DeFOREST Enterprises, Inc.
Amtec Center, 6421 Congress Avenue
Boca Raton, FL 33487
Tel: 561-994-9696
Fax: 561-994-9995
E-Mail: info@deforestent.com
Corrosion Inhibitors
| DeFOREST Home | About DeFOREST | DeFOREST Products | DeFOREST Technical Service |
|---|
The following products are anionic, water-soluble corrosion inhibitors primarily based on carboxylate chemistry. They are recommended for use in alkaline systems only, where no foam or low foam is essential. These corrosion inhibitors are non-phenolic, phosphate free, and hard water stable.They are inherently biodegradable and effective at low concentrations. Some contribute wetting properties and are very effective hydrotropes as well.
DeCORE IMT-100LF
A low foaming 100% active modified carboxylate for use in alkaline systems only. Extremely effective at low concentrations in both ferrous and non-ferrous applications. The final use solution should contain concentrations of 0.25-1.00% by weight, to prevent corrosion. Concentrations above 0.5% by weight may cause staining on cast iron without enhancing corrosion inhibition. The use of DeCORE IMT-100LF as a corrosion inhibitor is complemented by its lubricating, wetting and spreading properties.
DeTROPE CA-100
A 100% active modified carboxylate exhibiting low, quick-breaking foam. DeTROPE CA-100 is an outstanding hydrotrope and an excellent corrosion inhibitor for aluminum and ferrous metals. It is effective at low concentrations and will not leave a solid or waxy residue on metal surfaces upon drying. The corrosion inhibition and hydrotropic properties of DeTROPE CA-100 are complemented by good wetting properties as well. This multifunctional corrosion inhibitor is recommended for use in alkaline systems only.
DeCORE BE-85
A non-foaming, 85% active amine borate for use in alkaline systems only. Very effective corrosion inhibition properties on ferrous and non-ferrous metals when used at a minimum concentration of 1% by weight. Suggested for use in aqueous alkaline systems where zero foam is required. Prevents corrosion on aluminum but may cause staining.
DeCORE APCI-95
A 95% active, low foaming modified carboxylate for use in neutral or alkaline water based formulations. Very effective all-purpose corrosion inhibitor suitable for use on soft metals such as copper, brass, and magnesium. Also effective on aluminum, cast iron, steel, galvanized steel, and other ferrous and non-ferrous metals. Suitable for use in synthetic cutting fluids, parts and metal cleaners, aerosol products, water-based paints, and cooling tower additives. DeCORE APCI-95 is inherently biodegradable and non-phenolic. Does not contain nitrites, chromates, or phosphates.
APPLICATIONS
Each one of the products are recommended for use as corrosion inhibitors and may be used in the following applications:
|
|
|
CAST IRON CHIP TEST
Shows results of 24 hour test using grade 35 cast iron chips tested in solution on filter paper. Each solution contained % by weight of corrosion inhibitor plus hard water containing (100 ppm as CaCO3 and 71 ppm as CaCl2) at room temperature.
| A | = CONTROL | B | = DeCORE APCI-95 @ 1.00% | C | = DeCORE IMT-100LF @ 1.00% | D | = DeTrope CA-100 @ 1.00% | E | = DeCORE BE-85 @ 1.00% |
SUBMERSION TEST
Figures 2, 3, and 4 indicate the results of submersion tests. The top half of the panels were submerged into a liquid made up of % by weight of corrosion inhibitor plus hard water containing (100 ppm as CaCO3and 71 ppm as CaCl2) at room temperature. The other half of the panel was exposed to the vapor phase in closed containers.
Fig. 2 Panels are hot dipped Zn/Fe galvanized (unpolished) at 90 gms. and tested for one (1) yr.
Fig. 3 Indicates two (2) year results using bare #2024 aluminum at 0.063 inch thickness.
Fig. 4 A two (2) year result on cold rolled steel, SAE 1010, low carbon, 1/2 hard tempered @ 0.063 inch thickness.
![]() |
![]() |
| A = CONTROL | B = DeCORE IMT-100LF @0.50% | A = CONTROL | B = DeCORE IMT-100LF @1.00% | ||
| C = DeTROPE CA-100 @ 1.00% | D = DeCORE BE-85 @1.00% | C = DeTROPE CA-100 @ 1.00% | D = DeCORE BE-85 @1.00% |
* Produced best results
| A | = CONTROL | B | DeCORE IMT-100LF @ 0.25% | C | = DeTROPE CA-100 @ 0.25% | D | = DeCORE IMT-100LF @ 0.50% | E | = DeTROPE CA-100 @ 0.50% | ||||||
| F | = DeCORE BE-85 @ 0.50% | G | = DeCORE IMT-100LF @ 0.50% | H | = DeTROPE CA-100 @ 0.50% | I | = DeCORE BE-85 @ 0.50% |
* Produced best results
DeCORE APCI-95
CAST IRON CHIP TEST
Figure 5 shows the results of the Cast Iron Chip Test as previously described.
FIGURE 5
A, B and D show results of corrosion inhibition using 1.0% by weight of DeCORE APCI-95 in hard water. Control is designated as C.
SUBMERSION TEST
Figures 6 through 12 show the results of submersion tests as previously described.
| Panel A = 1.0% by weight of DeCORE APCI-95 | Panel B = 0.5% by weight of DeCORE APCI-95 | Panel C = Control |
![]() |
![]() |
|||
| FIGURE 6 | FIGURE 7 |
Fig. 6 Panels are #110-99.95% COPPER and tested for one (1) yr.
Fig. 7 Panels are #260 alloy-BRASS (30% Zn/70% Cu) and tested for one (1) yr.
![]() |
![]() |
|||
| FIGURE 8 | FIGURE 9 |
Fig. 8 Panels are #2024 bare ALUMINUM at 0.063 inch thickness and tested for one (1) yr.
Fig. 9 Panels are cold rolled STEEL, SAE 1010, low carbon, 1/2 hard tempered @ 0.063 inch thickness and tested for one (1) yr.
![]() |
![]() |
![]() |
||
| FIGURE 10 | FIGURE 11 | FIGURE 12 |
Fig. 10 Panels are Hot Dipped GALVANIZED steel - 70 gm. Zn/meter² and tested for one (1) yr.
Fig. 11 Panels are Hot Dipped GALVANIZED steel - 25 gm. Zn/foot² and tested for one (1) yr.
Fig. 12 Panels are electronically GALVANIZED steel - 45 gm. Zn/meter² and tested for one (1) yr.
RESULTS: All A and B Panels show no rust, with the exception of ALUMINUM Panel B which shows some rust at the 0.5% level only.
The information included and given throughout this website is drawn from data we believe to be reliable, but in all cases the user should check and confirm the suggestions and results in his/her own use before proceeding further. DeFOREST Enterprises, Inc. offers no warranties other than to guarantee the products are manufactured to specifications and cannot assume any liability or risk involved in the use of our products since these conditions of use are beyond our control. None of the suggestions or recommendations constitute freedom from any patents that may be existent in the field or be issued.
| DeFOREST Home | About DeFOREST | DeFOREST Products | DeFOREST Technical Service |
|---|
DeFOREST Enterprises, Inc. · Amtec Center, 6421 Congress Avenue · Boca Raton, FL 33487 · Voice: 561-994-9696 · Fax: 561-994-9995 · email: info@deforestent.com